This Acti9 iC60N is a low voltage miniature circuit breaker (MCB).

It is a 1P circuit breaker with 1 protected pole, 10A rated current and C tripping curve.

The rated short circuit breaking capacity goes up to 10kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 230VAC conforming to EN/IEC 60898-1 standard.

It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2.

This miniature circuit breaker protects circuits against short circuit and overload current.

Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit.

Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.

Its fast closing mechanism independent of manual operation improves its service life.

It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles.

The Ui rated insulation voltage is 500VAC.

Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost.

The product can be clipped on a DIN rail.

Its width is 2 pitches of 9mm.

Pollution degree is 3.

Overvoltage category is IV.

The product colour is white (RAL9003).

The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm.

The weight is 0.215kg.

According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure.

The operating temperature is -35°C to 70°C.

The storage temperature is -40°C to 85°C.

More Information
More Information
Attribute Value
SKU A9F74110
relative humidity 95-95 % at 55-55 °C
ambient air temperature for storage -40-85 °C
overvoltage category IV
pollution degree 3 conforming to EN 60947-2, 3 conforming to IEC 60947-2
ambient air temperature for operation -35-70 °C
number of protected poles 1
range of product iC60
product or component type Miniature Circuit Breaker
net weight 0.215 kg
mounting mode fixed
standards IEC 60898-1, IEC 60947-2, EN 60947-2, EN 60898-1
tropicalisation 2 conforming to IEC 60068-1
earth-leakage protection without
mechanical durability 20000 cycles
comb busbar and distribution block compatibility top or bottom: YES
device short name iC60N
breaking capacity 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2, 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1, 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2, 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2, 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2, 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
trip unit technology thermal-magnetic
range Acti 9
wire stripping length 14 mm for top or bottom connection
[Ics] rated service breaking capacity 27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz, 7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz, 27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz, 7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz, 15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz, 15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz, 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz, 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz, 10 kA 100 % conforming to EN 60947-2 - 72 V DC, 10 kA 100 % conforming to IEC 60947-2 - 72 V DC, 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC, 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
breaking capacity code N
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2, 6 kV conforming to EN 60947-2
product name Acti 9 iC60
network frequency 50/60 Hz
connections - terminals single terminal (top or bottom) 1-25 mm² rigid, single terminal (top or bottom) 1-16 mm² flexible
height 85 mm
mounting support DIN rail
compatibility code iC60
width 18 mm
depth 78.5 mm
operating altitude 0...2000 m
IP degree of protection IP20 conforming to IEC 60529, IP20 conforming to EN 60529
[In] rated current 10 A
curve code C
network type AC, DC
9 mm pitches 2
poles description 1P
colour white
tightening torque 2-2 N.m top or bottom
electrical durability 10000 cycles
device application distribution
control type toggle
[Ue] rated operational voltage 230 V AC 50/60 Hz, 220...240 V AC 50/60 Hz, 12...60 V AC 50/60 Hz, 100...133 V AC 50/60 Hz, 72 V DC, 12...60 V DC
magnetic tripping limit 8 x In +/- 20 %
local signalling trip indicator
utilisation category category A conforming to EN 60947-2, category A conforming to IEC 60947-2
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2, 500 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation yes conforming to IEC 60947-2, yes conforming to EN 60898-1, yes conforming to EN 60947-2, yes conforming to IEC 60898-1
contact position indicator yes
limitation class 3 conforming to EN 60898-1, 3 conforming to IEC 60898-1