Schneider Electric

Altistart 48 soft starter for asynchronous motor - ATS48 - 14.8 A - 230..415 V - 3..15 KW - ATS48D17Q

Out of stock
SKU
ATS48D17Q
40%
Special Price Rp 15.204.061 Regular Price Rp 25.340.101
Details

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.

The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.

It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.

This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.

There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.

It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.

It is an IP20 rated product.

Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).

It weighs 0.115kg.

This product is certified by CE.

It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.

This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.

It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.

Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.

A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.

Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

More Information
More Information
Attribute Value
SKU ATS48D17Q
product certifications CCC, GOST, CSA, DNV, UL, C-Tick, SEPRO, NOM 117, TCF
relative humidity 0-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for storage -25-70 °C
pollution degree level 3 conforming to IEC 60664-1
ambient air temperature for operation 40-60 °C (with current derating of 2 % per °C), -10-40 °C (without derating)
range of product Altistart 48
operating position vertical +/- 10 degree
product or component type Soft Starter & Variable Speed Drive
net weight 4.9 kg
standards EN/IEC 60947-4-2
device short name ATS48
range Altivar Softstarter ATS48
[Uc] control circuit voltage 220 - 15 % to 415 + 10 %, 50/60 Hz
minimum switching current 10 mA at 6 V DC for relay outputs
power range 4-6 kW at 200-240 V 3 phases, 7-11 kW at 380-440 V 3 phases, 4-6 kW at 380-440 V 3 phases, 7-11 kW at 200-240 V 3 phases, 15-25 kW at 380-440 V 3 phases, 2.2-3 kW at 200-240 V 3 phases
motor starter type soft starter
[Us] rated supply voltage 230...415 V - 15...10 %
electromagnetic compatibility conducted and radiated emissions level A conforming to IEC 60947-4-2, damped oscillating waves level 3 conforming to IEC 61000-4-12, electrostatic discharge level 3 conforming to IEC 61000-4-2, immunity to electrical transients level 4 conforming to IEC 61000-4-4, immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, voltage/current impulse level 3 conforming to IEC 61000-4-5, conducted and radiated emissions level B conforming to IEC 60947-4-2
device connection in the motor supply line, to the motor delta terminals
IcL starter rating 17 A for connection in the motor supply line for standard applications, 17 A for connection in the motor supply line for severe applications, 29 A for connection to the motor delta terminals for severe applications, 29 A for connection to the motor delta terminals for standard applications
control circuit consumption 30 W
factory setting current 14.8 A
discrete output type (LO1) logic output 0 V common configurable, (LO2) logic output 0 V common configurable, (R1) relay outputs fault relay NO, (R2) relay outputs end of starting relay NO, (R3) relay outputs motor powered NO
network frequency 47.5...63 Hz
height 275 mm
power dissipation in W 59 W for standard applications, 46 W for severe applications
marking CE
width 160 mm
depth 190 mm
vibration resistance 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-6, 1.5 mm (f= 2-13 Hz) conforming to EN/IEC 60068-2-6
operating altitude <= 1000 m without derating, > 1000...2000 m with current derating of 2.2 % per additional 100 m
IP degree of protection IP20
product destination asynchronous motors
protection type phase failure: line, thermal protection: motor, thermal protection: starter
connector type 1 RJ45
utilisation category AC-53A
motor power kW 7.5 kW at 230 V connection to the motor delta terminals for standard applications, 7.5 kW at 400 V connection in the motor supply line for standard applications, 11 kW at 400 V connection to the motor delta terminals for severe applications, 15 kW at 400 V connection to the motor delta terminals for standard applications, 3 kW at 230 V connection in the motor supply line for severe applications, 4 kW at 230 V connection in the motor supply line for standard applications, 5.5 kW at 230 V connection to the motor delta terminals for severe applications, 5.5 kW at 400 V connection in the motor supply line for severe applications
supply frequency 50...60 Hz - 5...5 %
shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27
function available external bypass (optional)
supply voltage limits 195-456 V
communication port protocol Modbus
product specific application heavy duty industry and pumps
analogue output type current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
maximum switching current logic output 0.2 A at 30 V DC, relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms, relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms
discrete input voltage 24 V <= 30 V
type of start start with torque control (current limited to 5 In)
supply inrush current 0.4...1.3 Icl adjustable
installed device 31
communication data link serial
discrete output number 2
discrete input type PTC, 750 Ohm at 25 °C, (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
physical interface RS485 multidrop
type of cooling natural convection
discrete input number 5
assembly style with heat sink
output absolute accuracy precision +/- 5 %
transmission rate 4800, 9600 or 19200 bps
discrete input logic positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA