Schneider Electric

Altivar 340 variable speed drive - 11kW- 400V - 3 phases - ATV340 Ethernet - ATV340D11N4E

Out of stock
SKU
ATV340D11N4E
37%
Special Price Rp 23.658.284 Regular Price Rp 37.552.832
Details

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.

The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.

It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.

This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.

There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.

It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.

It is an IP20 rated product.

Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).

It weighs 0.115kg.

This product is certified by CE.

It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.

This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.

It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.

Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.

A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.

Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

More Information
More Information
Attribute Value
SKU ATV340D11N4E
product certifications EAC, CSA, UL, TÜV, CTick
ambient air temperature for storage -40-70 °C
overvoltage category class III
pollution degree 2, 2 conforming to EN/IEC 61800-5-1
ambient air temperature for operation -15-60 °C, -15-50 °C without derating (vertical position), 50-60 °C with derating factor (vertical position)
motor power hp 20 hp for normal duty, 15 hp for heavy duty
maximum acceleration under vibratory load (during transport) 5 m/s² at 9...200 Hz
environmental class (during transport) class 2C3 according to EN 60721-3-2, class 2S1 according to EN 60721-3-2
supporting protocol for CAN false
continuous output current 32 A at 4 kHz for normal duty, 24 A at 4 kHz for heavy duty
number of inputs, bidirectional, not potential-free 0
isolation between power and control terminals
nominal output current 24 A
power loss per device current dependent 363 W
housing material plastic
supporting protocol for Foundation Fieldbus false
output voltage <= power supply voltage
range of product Altivar Machine ATV340
operating position vertical +/- 10 degree
product or component type Soft Starter & Variable Speed Drive
net weight 9.5 kg
mounting mode cabinet mount
standards EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 60721-3, IEC 61508, IEC 13849-1, UL 618000-5-1, UL 508C
range Altivar Machine ATV340
minimum switching current relay output R1B: 5 mA at 24 V DC, relay output R2C: 5 mA at 24 V DC
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
power range 7-11 kW at 380-440 V 3 phases, 7-11 kW at 480-500 V 3 phases
motor starter type variable speed drive
[Us] rated supply voltage 380...480 V, 380...480 V - 15...10 %
electromagnetic compatibility electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
analogue input type AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits, AI1 software-configurable temperature probe or water level sensor, AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits, AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
refresh time relay output (R1, R2): 5 ms (+/- 0.5 ms)
electrical connection control: screw terminal 0.2...2.5 mm²/AWG 24...AWG 12, screw terminal, clamping capacity: 0.2...2.5 mm² for control, line side: screw terminal 4...25 mm²/AWG 10...AWG 3, DC bus: screw terminal 4...25 mm²/AWG 10...AWG 3, motor: screw terminal 2.5...25 mm²/AWG 12...AWG 3, screw terminal, clamping capacity: 4...25 mm² for line side, screw terminal, clamping capacity: 4...25 mm² for DC bus, screw terminal, clamping capacity: 2.5...25 mm² for motor
discrete output type programmable output DQ1, DQ2 30 V DC 100 mA
maximum output frequency 0.599 kHz
optical interface present false
number of HW interfaces serial RS422 0
line current 28.8 A at 380 V (normal duty), 23.0 A at 480 V (normal duty), 34.7 A at 380 V (heavy duty), 27.7 A at 480 V (heavy duty), 34.7 A at 380 V without line choke (heavy duty), 27.7 A at 480 V without line choke (heavy duty), 33.9 A at 380 V with external line choke (normal duty), 27.2 A at 480 V with external line choke (normal duty), 35.1 A at 380 V with external line choke (heavy duty), 27.8 A at 480 V with external line choke (heavy duty)
base load current at high overload 24 A
speed drive output frequency 0.1-599 Hz
supporting protocol for AS-Interface Safety at Work false
asynchronous motor control profile variable torque standard, constant torque standard, optimized torque mode
number of HW interfaces industrial Ethernet 2
supporting protocol for SafetyBUS P false
variant standard version
with safety function Safe Speed Monitor (SSM) false
exchange mode half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
relay output number 2
supporting protocol for INTERBUS-Safety false
maximum deflection under vibratory load (during transport) 1.5 mm at 2...9 Hz
number of HW interfaces USB 0
nominal output power 11 W
supporting protocol for PROFINET CBA false
maximum associated fuse rating 63 A
maximum acceleration under vibrational stress (during operation) 5 m/s² at 9...200 Hz
1 phase low current possible false
maximum acceleration under vibratory load (during storage) 5 m/s² at 9...200 Hz
maximum transient current 35.2 A during 60 s (normal duty), 36 A during 60 s (heavy duty), 43.2 A during 2 s (normal duty), 43 A during 2 s (heavy duty)
number of HW interfaces serial RS232 0
input compatibility DI1...DI5: discrete input level 1 PLC conforming to EN/IEC 61131-2, PTI: pulse input level 1 PLC conforming to IEC 65A-68, STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
supporting protocol for Data-Highway false
with safety function Safe Position (SP) false
analogue output number 2
number of inputs, potential-free 0
permitted relative humidity (during operation) class 3K5 according to EN 60721-3
brake chopper integrated true
with safety function Safe Stop 1 (SS1) true
nominal switching frequency 4 kHz
number of input phases 3
braking to standstill by DC injection
supporting protocol for KNX false
supporting protocol for PROFIsafe false
application in industrial area permitted true
computer port true
network frequency 50...60 Hz
height 385 mm
power dissipation in W natural convection: 13 W at 380 V, switching frequency 4 kHz (heavy duty), forced convection: 241 W at 380 V, switching frequency 4 kHz (heavy duty), natural convection: 16 W at 380 V, switching frequency 4 kHz (normal duty), forced convection: 311 W at 380 V, switching frequency 4 kHz (normal duty)
marking CE
width 180 mm
depth 249 mm
vibration resistance 1.5 mm peak to peak (f= 2-19 Hz) conforming to EN/IEC 60721-3-3 class 3M3, 1 gn (f= 9-200 Hz) conforming to EN/IEC 60721-3-3 class 3M3
operating altitude <= 3000 m with current derating above 1000m
IP degree of protection IP20
protection type thermal protection: motor, safe torque off: motor, motor phase loss: motor, thermal protection: drive, safe torque off: drive, overheating: drive, overcurrent: drive, output overcurrent between motor phase and earth: drive, output overcurrent between motor phases: drive, short-circuit between motor phase and earth: drive, short-circuit between motor phases: drive, motor phase loss: drive, DC Bus overvoltage: drive, line supply overvoltage: drive, line supply undervoltage: drive, input supply loss: drive, exceeding limit speed: drive, break on the control circuit: drive
connector type connector(s)1 x RJ45, Modbus serial on front face, connector(s)1 x RJ45, Modbus serial for HMI on front face, connector(s)2 x RJ45, Ethernet IP/Modbus TCP on front face, 3 RJ45
motor power kW 15 kW for normal duty, 11 kW for heavy duty
supply frequency 50...60 Hz +/- 5 %
shock resistance 15 gn for 11 ms, class 3M3 conforming to EN/IEC 60721-3-3
network number of phases 3 phases
NEMA degree of protection not applicable
communication port protocol Ethernet/IP, Modbus TCP, Modbus serial
product specific application machine
analogue output type software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits, software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
maximum switching current relay output R1C on resistive load, cos phi = 1 : 3 A at 250 V AC, relay output R1C on resistive load, cos phi = 1 : 3 A at 30 V DC, relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC, relay output R2C on resistive load, cos phi = 1 : 5 A at 250 V AC, relay output R2C on resistive load, cos phi = 1 : 5 A at 30 V DC, relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC, relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
discrete output number 2
noise level 55.6 dB
discrete input type PTI programmable as pulse input: 0-30 kHz, 24 V DC (30 V), DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm, programmable
physical interface 2-wire RS 485
type of cooling forced convection
discrete input number 5
assembly style with heat sink
transmission rate 4.8 kbit/s, 9.6 kbit/s, 19.2 kbit/s, 38.4 kbit/s
discrete input logic positive logic (source) (DI1...DI5), < 5 V (state 0), > 11 V (state 1), negative logic (sink) (DI1...DI5), > 16 V (state 0), < 10 V (state 1), positive logic (source) (PTI), < 0.6 V (state 0), > 2.5 V (state 1), positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1), 16 preset speeds
prospective line Isc 22 kA
supporting protocol for TCP/IP true
with safety function Safe brake management (SBC/SBT) true
maximum acceleration under shock load (during transport) 70 m/s² at 22 ms
acceleration and deceleration ramps S, U or customized, linear adjustable separately from 0.01...9999 s
encoder protocol 1 Vpp, EnDat 2.2, resolver, RS 422, SSI 24V, SSI 5V, TTL/HTL
maximum deflection under vibratory load (during operation) 1.5 mm at 2...9 Hz
maximum acceleration under shock impact (during operation) 70 m/s² at 22 ms
number of HW interfaces PROFINET 0
maximum output voltage 480 V
transmission frame RTU
4 quadrant operation possible true
supporting protocol for SERCOS false
supporting protocol for INTERBUS false
with safety function Safe torque off (STO) true
volume of cooling air 128 m3/h
data format 8 bits, configurable odd, even or no parity
relative symmetric network frequency tolerance 5 %
input/output type programmable as logic input/output DQ1: 0-1 kHz, <= 30 V DC, 100 mA, programmable as logic input/output DQ2: 0-1 kHz, <= 30 V DC, 100 mA
supporting protocol for ASI false
apparent power 22.7 kVA at 480 V (normal duty), 23 kVA at 480 V (heavy duty)
supporting protocol for PROFIBUS false
relative symmetric mains voltage tolerance 10 %
EMC limit value (complied) true
base load current at low overload 32 A
with safety function Safe Direction (SDI) false
number of HW interfaces serial RS485 1
type of polarization no impedance
relay output type relay outputs R1A, relay outputs R1C electrical durability 100000 cycles, relay outputs R2A, relay outputs R2C electrical durability 100000 cycles
accuracy +/- 0.6 % AI1, AI2 for a temperature variation 60 °C analog input, +/- 1 % AQ1 for a temperature variation 60 °C analog output
permitted relative humidity (during storage) class 1K5 according to EN 60721-3
switching frequency 2...16 kHz adjustable, 4...16 kHz with derating factor
application in domestic and commercial area permitted false
maximum input current 34.7 A
analogue input number 2
motor slip compensation can be suppressed, adjustable, not available in permanent magnet motor law, automatic whatever the load
supporting protocol for PROFINET IO false
supporting protocol for MODBUS true
supporting protocol for DeviceNet Safety false
regulation loop adjustable PID regulator
operating element present true
permitted relative humidity (during transport) class 2K5 according to EN 60721-3
with safety function Safely Limited Position (SLP) false
method of access slave Modbus RTU, slave Modbus TCP
with safety function Safe Operating Stop (SOS) false
supporting protocol for DeviceNet false
supporting protocol for EtherNet/IP true
number of addresses 1-247
number of HW interfaces parallel 0
safety function STO (safe torque off) SIL 3
linearity error AI1, AI2: +/- 0.15 % of maximum value for analog input, AQ1: +/- 0.2 % for analog output
with safety function Safe programmable logic false
specific application machine
supporting protocol for BACnet false
supporting protocol for LON false
with sft fct Safe Stop 2 (SS2) false
design of frequency changer U converter
power loss static current independent 19 W
supporting protocol for SUCONET false
EMC filter class C3 EMC filter integrated
capacity of DC link 1500 µF
maximum acceleration under shock load (during storage) 70 m/s² at 22 ms
number of HW interfaces serial TTY 0
number of HW interfaces other 0
with safety function Safely Limited Speed (SLS) true
number of output phases 3
ambient air transport temperature -40-70 °C
environmental class (during storage) class 1C3 according to EN 60721-3-1, class 1S2 according to EN 60721-3-1
environmental class (during operation) class 3C3 according to IEC 60721-3-3, class 3S3 according to IEC 60721-3-3
maximum deflection under vibratory load (during storage) 1.5 mm at 2...9 Hz
sampling duration 2 ms +/- 0.5 ms (DI1...DI5) - discrete input, 5 ms +/- 1 ms (PTI) - pulse input, 1 ms +/- 1 ms (AI1, AI2) - analog input, 5 ms +/- 1 ms (AQ1) - analog output, 2 ms +/- 0.5 ms (DQ1, DQ2) - discrete input/output
supporting protocol for other bus systems false
synchronous motor control profile reluctance motor, permanent magnet motor
option card communication module, Profibus DP V1, communication module, Profinet, communication module, DeviceNet, communication module, CANopen, communication module, EtherCAT
PT. Telesindo Citra Sejahtera © 2021 All Rights Reserved.