Schneider Electric

EasyPact EZC circuit breaker EZC400N - TMD - 350 A - 3 poles 3d - EZC400N3350N

In stock
SKU
EZC400N3350N
50%
Special Price Rp 3.008.100 Regular Price Rp 6.016.200
Details

This is a 350A circuit breaker for EasyPact EZC400N.

This product can work below rated operational voltage(Ue) 440VAC at 50/60Hz.

The ultimate breaking capacity(Icu) is 50kA at 440V, in terms of complete range Ics=100%Icu(Ics= 50%Icu at 440V.

This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection.

It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva.

This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions.

Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking.

The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle.

This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker.

The fixed dimension is 140mm(width),255mm(height),110mm(Depth).

More Information
More Information
Attribute Value
SKU EZC400N3350N
range EasyPact EZC
product or component type MCCB
[In] rated current 400 A at 40 °C
trip unit technology thermal-magnetic
breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 40 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2, 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
ambient air temperature for operation -25-70 °C
ambient air temperature for storage -35-85 °C
control type toggle
mounting mode fixed
mechanical durability 10000 cycles
IK degree of protection IK07 conforming to EN 50102
network frequency 50/60 Hz
trip unit rating 350-350 A at 50 °C
earth-leakage protection without
breaking capacity code N
downside connection front
long time delay adjustment type fixed
long time pick-up adjustment type Ir fixed
upside connection front
[Ue] rated operational voltage 250 V DC conforming to IEC 60947-2, 440 V AC 50/60 Hz conforming to IEC 60947-2
product name EasyPact EZC
poles description 3P
protection type short-circuit protection, overload protection
standards JIS C8201-2-2, EN/IEC 60947-2, EN/IEC 60947-1, GB/T 14048.2
device application distribution
[Ics] rated service breaking capacity 18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2, 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2, 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
electrical durability category A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch 45 mm
device short name Easypact EZC400N
network type AC, DC
pollution degree 3 conforming to IEC 60947
protected poles description 3t
trip unit name TM-D
local signalling positive contact indication
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
height 255 mm
depth 140 mm
width 185 mm
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
compatibility code EZC400
IP degree of protection IP20 conforming to IEC 60529
utilisation category category A
suitability for isolation yes conforming to IEC 60947-2
PT. Telesindo Citra Sejahtera © 2025 All Rights Reserved.