Schneider Electric

Modicon TM3 - 2 analog or temperature inputs, 1 analog output (screw) 24Vdc - TM3TM3

Out of stock
SKU
TM3TM3
33%
Special Price Rp 3.968.933 Regular Price Rp 5.923.780
Details

This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262.

The analogue output module provides 2 outputs with 11bit + sign and 12bit resolution.

It is an output module with a rated supply voltage of 24V DC and a current consumption of 70mA at 24V DC via external supply full load.

This product is capable of controlling variable speed drives or any device equipped with a current or voltage input.

There is an insulation between output and supply at 1500V AC, output and internal logic at 500V AC.

It is furnished with removable screw terminal for electrical connection with 5.08mm pitch adjustment for outputs.

It is an IP20 rated product.

Its dimensions are 23.6mm (Width) x 70mm (Depth) x 90mm (Height).

It weighs 0.115kg.

This product is certified by CE.

It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards.

This module is compatible with Modicon M262, Modicon M241, Modicon M251 and Modicon M221 logic controller.

It supports top hat type TH35-15, top hat type TH35-7.5 rail conforming to IEC 60715 and plate or panel with fixing kit mount.

Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism.

A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers.

Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.

More Information
More Information
Attribute Value
SKU TM3TM3
relative humidity 10-95 %, without condensation (in operation), 10-95 %, without condensation (in storage)
ambient air temperature for storage -25-70 °C
pollution degree 2
ambient air temperature for operation -10-55 °C horizontal installation, -10-35 °C vertical installation
resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2, 4 kV on contact conforming to EN/IEC 61000-4-2
range of product Modicon TM3
product or component type Relay & Power Supply
current consumption 55 mA at 24 V DC via external supply no load, 55 mA at 5 V DC via bus connector no load, 60 mA at 5 V DC via bus connector full load, 80 mA at 24 V DC via external supply full load
net weight 0.115 kg
standards EN/IEC 61010-2-201, EN/IEC 61131-2
range Modicon TM3
range compatibility Modicon M221, Modicon M241, Modicon M251, Modicon M262
[Us] rated supply voltage 24 V DC
analogue input type current 4...20 mA, current 0...20 mA, voltage 0...10 V, voltage - 10...10 V, thermocouple - 200...1000 °C with thermocouple J, thermocouple - 200...1300 °C with thermocouple K, thermocouple 0...1760 °C with thermocouple R, thermocouple 0...1760 °C with thermocouple S, thermocouple 0...1820 °C with thermocouple B, thermocouple - 200...400 °C with thermocouple T, thermocouple - 200...1300 °C with thermocouple N, thermocouple - 200...800 °C with thermocouple E, thermocouple 0...2315 °C with thermocouple C, Ni 100/Ni 1000 temperature probe - 60...180 °C, Pt 100 temperature probe - 200...850 °C, Pt 1000 temperature probe - 200...600 °C
electrical connection 11 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for inputs, outputs and supply
immunity to microbreaks 10 ms
repeat accuracy +/-0.5 %FS for input, +/- 0.4 %FS for output
analogue output number 1
insulation between output and supply at 1500 V AC, between output and internal logic at 500 V AC, between input and supply at 1500 V AC, between input and internal logic at 500 V AC
conversion time 100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple, 100 ms + 100 ms per channel + 1 controller cycle time for analogue input temperature probe, 10 ms + 10 ms per channel + 1 controller cycle time for analogue input voltage/current
analogue input resolution 16 bits, 15 bits + sign
height 90 mm
mounting support top hat type TH35-15 rail conforming to IEC 60715, top hat type TH35-7.5 rail conforming to IEC 60715, plate or panel with fixing kit
marking CE
width 23.6 mm
depth 70 mm
vibration resistance 3.5 mm at 5-8.4 Hz on DIN rail, 3 gn at 8.4-150 Hz on DIN rail
operating altitude 0...2000 m
IP degree of protection IP20
local signalling 1 LED (green) for PWR
load type resistive
absolute accuracy error +/- 6 °C at 25 °C for thermocouple R, S 0...200 °C, +/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C, +/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C, +/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C, +/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C, +/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C, +/- 0.1 % of full scale at 25 °C for analogue input voltage/current, +/- 0.1 % of full scale at 25 °C for thermocouple C 0...2315 °C, +/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe, +/- 0.1 % of full scale at 25 °C for thermocouple R, S 200...1760 °C, +/- 0.1 % of full scale at 25 °C for thermocouple B 300...1820 °C, +/- 0.1 % of full scale at 25 °C for thermocouple K 0...1300 °C, +/- 0.1 % of full scale at 25 °C for thermocouple J 0...1000 °C, +/- 0.1 % of full scale at 25 °C for thermocouple E 0...800 °C, +/- 0.1 % of full scale at 25 °C for thermocouple T 0...400 °C, +/- 0.1 % of full scale at 25 °C for thermocouple N 0...1300 °C, +/- 0.1 % of full scale at 25 °C for analogue output voltage/current
shock resistance 15 gn for 11 ms
supply voltage limits 20.4-28.8 V
type of cable twisted shielded pairs cable <30 m for input/output circuit
surge withstand 1 kV power supply common mode conforming to EN/IEC 61000-4-5, 0.5 kV power supply differential mode conforming to EN/IEC 61000-4-5, 1 kV I/O common mode conforming to EN/IEC 61000-4-5, 0.5 kV I/O differential mode conforming to EN/IEC 61000-4-5
resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3, 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
resistance to fast transients 1 kV (I/O) conforming to EN/IEC 61000-4-4
electromagnetic emission radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to EN/IEC 55011, radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230-1000 MHz conforming to EN/IEC 55011
analogue output type current: 4...20 mA, current: 0...20 mA, voltage: 0...10 V, voltage: - 10...10 V
analogue input number 2
sampling duration 10 ms, analogue input type: voltage/current, 100 ms, analogue input type: voltage/current, 100 ms, analogue input type: thermocouple, 100 ms, analogue input type: temperature probe
input impedance <= 50 Ohm current, >= 1 MOhm voltage, >= 1 MOhm thermocouple, >= 1 MOhm temperature probe
LSB value 0.15 mV 0...10 Vvoltage, 0.30 mV - 10...10 Vvoltage, 0.30 µA 0...20 mAcurrent, 0.244 µA 4...20 mAcurrent, 0.1 °Ctemperature probe, 0.1 °Cthermocouple, 2.44 mV 0...10 V voltage, 4.88 mV - 10...10 V voltage, 4.88 µA 0...20 mA current, 3.91 µA 4...20 mA current
resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6, 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
storage altitude 0-3000 m
analogue output resolution 12 bits
temperature drift +/- 0.006 %FS/°C
stabilisation time 1 ms
load impedance ohmic 1 kOhm voltage, 300 Ohm current
output ripple 20 mV
non-linearity +/- 0.01 %FS, analogue output type: analog output, +/- 0.1 %FS, analogue input type: analog input
cross talk <= 1 LSB
resistance to magnetic fields 30 A/m conforming to EN/IEC 61000-4-8
permissible continuous overload 13 V, analogue input type: voltage, 40 mA, analogue input type: current
PT. Telesindo Citra Sejahtera © 2021 All Rights Reserved.